Magnetic Trap
Magnetic Trap, is pecifically designed for the extraction of ferrous materials and enhancing the purity grade of the material from liquids and slurries pipelines.
The Magnetic Trap contains Stainless steel housing and magnetic tubes positioned in the material flow. Stainless steel housing contains input and output connections to pass the fluid.
Magnetic trap can protect product purity and preventing abrasive wear, preventing pumps from jamming, reducing damage and maintenance to mixers, filters, pumps, refiners and other processing machinery handling paper, chemical slurries and other liquid materials. end assures a product free of iron contamination.
Magnetic trap can protect product purity and preventing abrasive wear, preventing pumps from jamming, reducing damage and maintenance to mixers, filters, pumps, refiners and other processing machinery handling paper, chemical slurries and other liquid materials. end assures a product free of iron contamination.
Make an inquiry
Introduction:
The Liquid Pipeline Magnetic Separator, also known as a Magnetic Trap, is pecifically designed for the extraction of ferrous materials and enhancing the purity grade of the material from liquids and slurries pipelines.
Structure:
The Liquid Pipeline Magnetic Separator, also known as a Magnetic Trap, is pecifically designed for the extraction of ferrous materials and enhancing the purity grade of the material from liquids and slurries pipelines.
Structure:
The Magnetic Trap contains Stainless steel housing and magnetic tubes positioned in the material flow. Stainless steel housing contains input and output connections to pass the fluid.
The Magnetic Trap is manufactured of either standard-strength Ferrite (for larger tramp metal capture) or high-strength Rare Earth Neodymium (for fine iron and abraded stainless steel).
The high-strength Rare Earth Neodymium is tested and certified to 12000 gauss on the contact surface, which has powerful magnetic forces to remove weakly magnetic or very fine iron contaminants and Prevent abrasive wear, prevent pumps from jamming and assure yourself a product free of iron contamination from liquids and slurries pipeline.
And the standard-strength Ferrite is 1500gauss, which is used to remove strong magnetic or large iron contaminants from liquids and slurries pipelines.
Installation:
Installation:
Magnetic Trap may be installed horizontally, vertically,or at an angle without affecting their magnetic efficiency.
Magnetic Trap can directly connect with the liquid material pipeline.
when material flow enters the Magnetic Trap to impinge against the magnetic tubes and filter through the magnetic field.
In the course of manual cleaning, draw the magnetic tubes and get rid of ferrous materials.
Application and benefit in application industry:
How to clean absorb metal in magnetic trap:
In the course of manual cleaning, draw the magnetic tubes and get rid of ferrous materials.
Application and benefit in application industry:
Magnetic Trap is used widely in the processing industry to remove metal contamination from liquids and slurries. The magnetic tubes within liquid Magnetic Trap for the Liquid line catch the ferrous impurities contamination in a product and it flows through the processing line thereby protecting product purity and preventing abrasive wear, preventing pumps from jamming, reducing damage and maintenance to mixers, filters, pumps, refiners and other processing machinery handling paper, chemical slurries and other liquid materials. end assures a product free of iron contamination.
The benefits of using a liquid magnetic trap include improved product quality, reduced equipment downtime, and increased production efficiency. By removing ferrous and magnetic particles from the liquid stream, the trap helps to prevent equipment damage and product contamination, leading to higher product yields and increased profits.
How to clean absorb metal in magnetic trap:
To clean the iron absorbed in a liquid magnetic trap, the cleaning mechanism is typically activated to remove the captured particles from the magnetic tubes. Depending on the type of cleaning mechanism, this can be done manually or automatically. Once the particles have been removed, the trap is ready to be used again.
please tell me liquid magnetic trap description,installation,work pricipal,instructure,industry application and benifit in application industry and how to clean the iron in absorb magnet
Technical specification:
Model |
Application |
diameterφ(mm) |
Weight(kg) |
A |
B |
C |
H |
N |
M |
φ1 |
φ2 |
LQRO-50 |
Liquid |
50 |
19 |
115 |
85 |
250 |
270 |
8 |
14 |
125 |
150 |
LQRO-65 |
65 |
27.3 |
120 |
105 |
360 |
380 |
8 |
14 |
165 |
192 |
|
LQRO-80 |
80 |
30.5 |
130 |
155 |
360 |
380 |
8 |
18 |
210 |
240 |
|
LQRO-100 |
100 |
45 |
130 |
180 |
380 |
405 |
8 |
18 |
240 |
270 |
|
LQRO-125 |
125 |
56.5 |
145 |
190 |
420 |
430 |
8 |
18 |
270 |
300 |
|
LQRO-150 |
150 |
72 |
180 |
190 |
450 |
465 |
8 |
18 |
300 |
330 |
|
LQRO-200 |
200 |
120 |
235 |
250 |
500 |
520 |
8 |
18 |
360 |
390 |
|
LQRO-250 |
250 |
19 |
265 |
280 |
530 |
640 |
12 |
18 |
395 |
425 |
|
LQRO-300 |
300 |
270 |
285 |
300 |
600 |
680 |
12 |
23 |
450 |
485 |
|
LQRO-350 |
350 |
350 |
325 |
340 |
680 |
750 |
12 |
23 |
500 |
540 |
|
LQRO-400 |
400 |
420 |
340 |
355 |
750 |
800 |
16 |
23 |
550 |
600 |